The Antares features different applicators, Clusters, and Probes, designed with various configurations and combinations of LEDs and Laser to meet clinical needs across different body areas.
The Antares is a photobiomodulation device designed for use in various health and aesthetic fields. It supports different applicators—either individual probes or grouped laser and/or LED clusters—offering a fresh perspective on light-based therapies.
NEW
GENERATION
LEDs
Featuring enhanced power, reduced beam divergence, and quasi-monochromatic emission, its 13-diode clusters can reach up to 6500 mW—allowing treatment of large body areas in less time.
NEW
GENERATION LEDs
Featuring enhanced power, reduced beam divergence, and quasi-monochromatic emission, its 13-diode clusters can reach up to 6500 mW—allowing treatment of large body areas in less time.
Extensive research optimized uniform light distribution across the treatment zone, ensuring consistent energy density. A specialized layout positions the LEDs at the ideal distance from the skin.
The clusters leverage proprietary reflective technology to focus light more precisely on the application area, enhancing clinical outcomes.
The clusters leverage proprietary reflective technology to focus light more precisely on the application area, enhancing clinical outcomes.
EVIDENCE-BASED
PROTOCOLS
FOR:
EVIDENCE-BASED PROTOCOLS FOR:
ANTARES EXCLUSIVE
These unique protocols combine multiple wavelengths in the same session, enabling:
ANTARES EXCLUSIVE
These unique protocols combine multiple wavelengths in the same session, enabling:
A built-in verification system confirms LED/laser emission each time the device is powered on or when an applicator is reconnected or replaced—required before use.
The Antares features different applicators, Clusters, and Probes, designed with various configurations and combinations of LEDs and Laser to meet clinical needs across different body areas.
Small Cluster 1 (P1) – LED RGB + 808 nm Laser
Arthritis, skin healing, chronic pain, lymph dynamics, lateral epicondylitis, herpes, ligament injuries, trigger points, pre/post-exercise, burns, muscle strain, carpal tunnel, tendinopathy, non-infected ulcers, photodynamic therapy.
Small Cluster 2 (P2) – LEDs 630 nm & 850 nm
Red and infrared LEDs, versatile for rehabilitation and aesthetic dysfunctions; cost-effective. Contact area: ~20 cm², continuous or pulsed.
Skin photoregeneration, photorejuvenation, hair phototherapy, hyperpigmentation, lipolysis, post-plastic surgery, rosacea, photodynamic therapy.
Arthritis, skin healing, chronic pain, lymph dynamics, lateral epicondylitis, herpes, ligament injuries, trigger points, pre/post-exercise, burns, muscle strain, carpal tunnel, tendinopathy, non-infected ulcers, photodynamic therapy.
Large Cluster 1 (G1) – LEDs 590 nm, 630 nm & 850 nm
39 LEDs for larger body areas, enabling shorter sessions. Contact area: ~80 cm², continuous or pulsed.
Cellulite, acne healing, hypertrophic scars, lymphatic drainage, skin laxity, photorejuvenation, photoregeneration, hair phototherapy, hyperpigmentation, lipolysis, post-plastic surgery, collagen remodeling, rosacea, photodynamic therapy.
Arthritis, skin healing, chronic pain, lymph dynamics, lateral epicondylitis, herpes, ligament injuries, trigger points, pre/post-exercise, burns, muscle strain, carpal tunnel, tendinopathy, non-infected ulcers, photodynamic therapy.
Large Cluster 2 (G2) – LEDs 410 nm, 450 nm & 630 nm
Superficial-tissue targeting. Contact area: ~80 cm².
Acne, cellulite, acne healing, microbial control, skin photodescontamination, photoregeneration, photorejuvenation, hair phototherapy, lipolysis, post-plastic surgery, rosacea, photodynamic therapy.
skin healing, herpes, bacterial inhibition, burns, non-infected ulcers.
Acne; acne scar; hypertrophic scar; lymphatic drainage; bruising; skin flaccidity; skin photoregeneration; photo-rejuvenation; scalp phototherapy; hyperchromia; lipolysis; onychomycosis PDT; post-plastic surgery; collagen remodeling; rosacea; photodynamic therapy.
Artrite; cicatrização de pele; dor crônica; drenagem linfática; epicondilite lateral; herpes; lesão ligamentar; pontos gatilhos; pré e pós atividade física; queimaduras; estiramento muscular; síndrome do túnel do carpo; tendinopatia; úlceras não contaminadas.
Acne, acne healing, bruising, photoregeneration, photorejuvenation, hair phototherapy, onychomycosis (photodynamic therapy), post-surgery, rosacea, photodynamic therapy.
Skin healing, herpes, burns, non-infected ulcers.
PROBE 2 – LED 850NM
Infrared probe with excellent cost-benefit for rehabilitation.
Hypertrophic scars, lymphatic drainage, hyperpigmentation, post-plastic surgery.
Arthritis, chronic pain, lymphatic drainage, lateral epicondylitis, ligament injury, trigger points, muscle strain, carpal tunnel syndrome, tendinopathy.
Probe 3 – Red Laser 660 nm (adjustable to ≤ 180 mW)
Contact area: ~0.5 cm². Continuous or pulsed emission.
Acne healing, photoregeneration, hair phototherapy, rosacea, ILIB (Intravenous Laser Irradiation of Blood), photodynamic therapy.
Skin healing, herpes, burns, non-infected ulcers, ILIB.
Conventional technique and frequencies (Nogier, Reininger, Bahr, S-frequencies).
Probe 4 – Infrared Laser 808 nm (adjustable to ≤ 180 nW)
Contact area: ~0.7 cm². Continuous or pulsed emission.
Hypertrophic scars, lymphatic drainage, hyperpigmentation, ILIB.
Arthritis, chronic pain, lymphatic drainage, lateral epicondylitis, ligament injury, trigger points, muscle strain, carpal tunnel syndrome, tendinopathy, ILIB.
Laserpuntura:
Conventional technique and frequencies (Nogier, Reininger, Bahr, S-frequencies).
Probe 5 – Infrared Laser 904 nm (average power ~70 nW, peak power 70 W, pulsed)
Highly penetrating wavelength. Contact area: ~0.7 cm².
Deep arthritis, chronic pain, lymphatic drainage, lateral epicondylitis, ligament injuries, trigger points, muscle strain, bone repair, carpal tunnel syndrome, tendinopathy.
Conventional technique and frequencies (Nogier, Reininger, Bahr, S-frequencies).
The ANTARES is a microcontrolled photobiomodulation therapy device developed for use in different areas of health and aesthetics. The ANTARES can operate with single applicators (probes) and larger applicators (clusters), which offer a new dimension of Light Therapy.
Includes: IEC PP female cable (2 × 0.75 mm² × 1500 mm), 5 A fuse, digital operations manual, protective goggles (200–1200 nm) for operator and patient.
Optional accessories: interlock connector; Probes P1–P5; Clusters P1–P2, G1–G3.
Dimensions
Place probe or cluster in contact with skin, without pressure. Refer to provided examples for correct positioning.
During photobiomodulation, adjust wavelength and dose to target chromophores—this yields significant clinical effects.
Position patient comfortably (seated or lying).
Maintain at least 20 cm between operator/patient and equipment.
Clean treatment area with water, neutral soap, and 0.5% alcoholic chlorhexidine or 70% medicinal alcohol; allow drying.
Clean applicator before and after each session; clean lens with lightly moistened cotton and disinfectant.
Re-examine skin post-treatment to ensure maximum light energy reaches target tissues and minimize irritation.
Photon irradiation of low-energy light (LLLT or LEDT) can modulate biological processes—this is called photobiomodulation. Clusters treat larger areas with multiple wavelengths; Probes target specific points and wavelengths with up to 180 mW power.
Pregnant women or those intending to become pregnant; using without protective goggles; aiming at eyes of humans or animals; areas with steroid injections in past 2–3 weeks; symptomatic pain without known etiology; over carotid sinus nerves, especially in sensitive patients; neck thyroid area; cancer lesions; epilepsy photoseizure patients; near growth plates until growth ends; areas prone to bleeding post-trauma or fracture; abdomen during pregnancy.
Use light emission check; wear goggles, place applicator on the device’s CHECK receptor; once “EMISSION OK” appears, device switches to the selected mode (Aesthetic, Rehabilitation, Laserpuntura, Custom, etc.).
Facial: Cluster P1;
Body: Cluster G3.
Yes—though it doesn’t include the ILIB wristband; program the parameters and perform the technique manually.
First, identify your field (Rehabilitation vs. Aesthetics); second, size of treatment area; third, desired tissue penetration (wavelength).