Heccus Turbo

new

HECCUS
TURBO

Combined Therapy
Platform with
Ultrasound and Currents

The Heccus Turbo device is an innovative combined therapy platform for body aesthetic treatments, with therapeutic modalities of high-power ultrasound with flat transducer, Aura Massage, Aussie Current, Polarized Current, and High Volt Current.

Heccus Turbo

81

Watts

THE HIGHEST POWER
on the Market!

Ultrasonic energy delivered in a three-dimensional manner with the highest market power, featuring 81 Watts and a larger effective radiation area of 27 cm².

COMBINED THERAPY

ULTRASOUND + CURRENTS

The evolution of therapeutic currents.
An exclusive technology from Ibramed, indicated for various treatments with the purpose of muscle strengthening, analgesia, and lymphatic drainage.

Heccus Turbo

Heccus Turbo features 8 output channels for Aussie Current and 2 channels for Polarized and High Volt currents.

Exclusive

TURBO Mode

For greater efficiency, Heccus Turbo offers the exclusive TURBO mode, in which the duty cycle (%) is automatically increased or decreased according to the intensity in W/cm², ensuring higher treatment efficacy and better results!

Exclusive in the Market with

Anodized Crystals

The equipment is the only one on the market with anodized crystals, which provide greater effectiveness of electrical currents in the treatment area, in addition to enabling the exclusive electrodynamic transducer technique — a differential that optimizes treatments with therapeutic currents in large body areas.

SCIENCE +

CLINICAL PRACTICE

Pre-Programmed Mode

Heccus comes with pre-programmed protocols – scientifically supported by our research team – which guide the treatment according to usage indications and the therapeutic goal. Thus, the system directs to the most appropriate treatment modality.

2-in-1

Applicator

The ultrasound allows automatic adjustment of the 1.1 MHz and 3.3 MHz frequencies in the same applicator, with no need to change the transducer for therapy.

Exclusive

Duet

System

The Heccus Turbo device features the Duet System technology, which enables different treatments in more than one body region at the same time, reducing session time and optimizing results.

Automated

Systems

Automatic Calculation of Treatment Time

Simply measure the treatment area with the transducer itself, press the corresponding number on the screen, and the equipment calculates the correct application time.

Automatic Calculation of Intensity

 Just check the patient’s adipose layer, and the equipment automatically adjusts the ideal intensity for the treatment.

Heccus Turbo

facilidade e conforto

controle

remoto

O Heccus turbo possui um controle remoto, que permite acionamento do start/stop e programação da intensidade da corrente da terapia combinada, mesmo com alguma distância do equipamento.

Additional Information

Product Description

HECCUS TURBO is a device that features 5 therapies: therapeutic ultrasound at 1.1 MHz and 3.3 MHz frequencies, Aussie Current, Polarized Current, High Volt Current, and Aura Massage. It has an applicator with 3 ultrasound emitters with 9 cm² crystals, totaling an area of 27 cm² and a maximum effective power of 3 W/cm², providing a maximum output of 81 Watts with the option to select the operating frequency of 1.1 MHz or 3.3 MHz.

In addition, it allows different application modes: isolated ultrasound, isolated currents, combined therapy (Ultrasound + Therapeutic Currents — Aussie Current, Polarized Current, and High Volt Current), and the EXCLUSIVE DUET MODE, enabling two therapies to be used simultaneously in different areas.

Indications

THERAPEUTIC ULTRASOUND

AUSSIE CURRENT

POLARIZED CURRENT

HIGH VOLT CURRENT

Ultrasound

  • Pregnant women or potentially pregnant uterus;

     

  • Undiagnosed pain treatment;

     

  • Neoplastic areas or areas where the tumor has been removed;

     

  • Application over the eyes;

     

  • Presence of open wounds at the treatment site;

     

  • Application over growing bone epiphyses;

     

  • Ischemic areas, where blood supply cannot meet metabolic demand, potentially resulting in necrosis;

     

  • Areas previously treated with radiotherapy;

     

  • Gonads, to avoid heating;

     

  • Application over the cardiac area;

     

  • Areas of thrombophlebitis, deep vein thrombosis, embolism, and severe atherosclerosis;

     

  • In cases of suspected severe infectious disease, where for general medical purposes it is advisable to suppress heat or fever;

     

  • Over the stellate ganglion, spinal cord, and skull;

     

  • Areas of reduced sensitivity or circulation, or over anesthetized areas

Implanted Electronic Device:: it is recommended that patients with implanted electronic devices (e.g., pacemaker, deep brain stimulation device) are not subjected to therapy with electronic equipment, unless prior authorization has been obtained from a specialized physician.


Currents

  • Pregnancy or intention to become pregnant;

  • Heart disease;

  • Tumor at the site;

  • Uncontrolled hypertension and diabetes;

  • Allergic reactions resulting from the use of electrostimulation;

  • Infectious processes;

  • Epilepsy.
Implanted Electronic Device: it is recommended that patients with implanted electronic devices (e.g., pacemaker, deep brain stimulation device) are not subjected to therapy with electronic equipment, unless prior authorization has been obtained from a specialized physician.
Hearing Aids: hearing aids must be removed during the session. If subjected to electrical stimulation, hearing aids may be damaged and present operational irregularities.

Contraindications Only for Polarized Current

  • Internal and external metallic components;

  • Open wounds.

Contraindications Only for Muscle Strengthening with Aussie Current

  • Muscle injuries, tendinitis, and tenosynovitis;

  • Acute muscle disorders, myositis, dystrophies, myopathies; non-consolidated tissues, fractures, ruptures of tendons, muscles, and ligaments.

Aura Massage

  • Acute inflammations, with or without pathogens involved;

  • Active tuberculosis;

  • Acute venous disease;

  • Erysipelas;

  • Heart disorders and diseases, especially congestive, decompensated cardiac edema, or cardiac arrhythmia;

  • Pregnancy;

  • Hypersensitivity to electrostatic fields;

  • Skin infectious diseases;

  • Deep vein thrombosis;

  • Untreated vascular diseases;

  • Renal failure;

  • Epilepsy.

Technical Information

Dimensions

Voltage

Receive a Special Offer!

The Best-Selling on the Market!

Innovative Platform for Combined Therapies

Heccus Turbo

Dúvidas frequentes sobre este equipamento IBRAMED

Informações Técnicas

Dimensões

Voltagem

Informações Técnicas

Dimensões

Voltagem

Informações Técnicas

Dimensões

Voltagem